Figure 16-3: Specifying the Number of Transceiver Interfaces for Arria V GZ and Stratix V Devices
The Transceiver Reconfiguration Controller includes an Optional interface grouping parameter.
Transceiver banks include six channels. For a ×4 variant, no special interface grouping is required because
all 4 lanes and the TX PLL fit in one bank.
Note:
Although you must initially create a separate logical reconfiguration interface for each lane and TX
PLL in your design, when the Quartus II software compiles your design, it reduces the original
number of logical interfaces by merging them. Allowing the Quartus II software to merge reconfi‐
guration interfaces gives the Fitter more flexibility in placing transceiver channels.
Note: You cannot use SignalTap to observe the reconfiguration interfaces.
UG-01127_avst
2014.12.15
Connecting the Transceiver Reconfiguration Controller IP Core
16-3
Transceiver PHY IP Reconfiguration
Altera Corporation