Altera Parallel Flash Loader IP Instrukcja Użytkownika Strona 51

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 57
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 50
Flash Access Mode
Configura‐
tion Data
Option
Flash Data
Width (bits)
DCLK Ratio = 1, 2, 4, or 8
(9)
FPP Mode PS Mode
For Normal Mode and Burst Mode:
C
access
= T
access
*F
clk
+1
Total Clock Cycles (from nRESET asserted high to N bytes of data clocked out)
= C
overhead
+ max(C
flash
, C
cfg
)*N
Total Configuration Time = Total Clock Cycle/ PFL Input Clock
For Page Mode
C
access
=[(T
access
*F
clk
+1) + (T
page_access
*F
clk
*15)]/16
Total Clock Cycles (from nRESET asserted high to N bytes of data clocked out)
= C
overhead
+ max (C
flash
, C
cfg
)*N
Total Configuration Time = Total Clock Cycle/ PFL Input Clock
For FPP (×8)
Total Clock Cycles (from nRESET asserted high to N bytes of data clocked out)
C
flash
remains the same
For FPP (×16)
Total Clock Cycles (from nRESET asserted high to N word of data clocked out)
C
flash
= C
flash
× 2 (×2 of C
flash
from FPP ×8)
For FPP (×32)
Total Clock Cycles (from nRESET asserted high to N double word of data clocked out)
C
flash
= C
flash
× 4 (×4 of C
flash
from FPP ×8)
Configuration Time Calculation Examples
The following are the configuration time calculation examples for normal mode, page mode, and burst
mode:
Note:
Any reference to the core clock speed of 100 MHz is only an example of the configuration time
calculation and not a recommendation of the actual clock.
(9)
Ratio between input clock and DCLK output clock. For more information, see related information
(10)
Spansion page mode support is only available in the Quartus II software versions 8.0 onwards.
UG-01082
2015.01.23
Specifications
51
Parallel Flash Loader IP Core User Guide
Altera Corporation
Send Feedback
Przeglądanie stron 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 57

Komentarze do niniejszej Instrukcji

Brak uwag