3–18 Altera Corporation
PowerPlay Early Power Estimator User Guide For Cyclone II FPGAs May 2006
PowerPlay Early Power Estimator Spreadsheet Inputs
also verifies that the V
CCIO
levels match the I/O standards for each I/O
bank. If there is a discrepancy, it is displayed in the Bank Voltage Check
column, as shown in Figure 3–14.
Figure 3–13. I/O Standard Verification
Figure 3–14. PowerPlay Early Power Estimator Spreadsheet Checks for V
CCIO
Inconsistencies
The PowerPlay early power estimator shows the I
CCIO
listed for each
bank. Select the V
CCIO
in the V
CCIO
column. The PowerPlay early power
estimator checks whether or not your selected V
CCIO
is acceptable based
on the I/O standard and I/O bank combination in the listed modules. If