Chapter 3: Development Board Setup 3–3
Factory Default Switch and Jumper Settings
November 2013 Altera Corporation Cyclone V SoC Development Kit
User Guide
2. Set the DIP switch bank (SW3) to match Table 3–2 and Figure 3–1.
In the following table, up and down indicates the position of the switch with the
board orientation as shown in Figure 3–1.
Important: The default MSEL pin settings are set to all zeroes (ON) to select the fast
passive parallel x16 mode. For power-up configuration from MAX V and CFI
flash, ensure that the MAX V design uses this same mode as does in the design in
the <install dir>\kits\cycloneVSX_5csxfc6df31_soc\examples\max5 directory.
3FACT LOAD
Switch 3 has the following options:
ON (0) = Load the factory design starting at
0x20000 at power up.
OFF (1) = Parallel flash loader (PFL) disabled.
OFF
4 Security
Switch 4 has the following options:
ON (0) = On-Board USB Blaster II sends
FACTORY command at power up
OFF (1) = On-Board USB Blaster II does not
send FACTORY command at power up
OFF
Table 3–2. SW3 DIP Switch Settings
Switch
Board
Label
Function
Default
Position
1 MSEL0
Switch 1 has the following options:
ON (up) = MSEL0 is 0.
OFF (down) = MSEL0 is 1.
ON
2 MSEL1
Switch 2 has the following options:
ON (up) = MSEL1 is 0.
OFF (down) = MSEL1 is 1.
ON
3 MSEL2
Switch 3 has the following options:
ON (up) = MSEL2 is 0.
OFF (down) = MSEL2 is 1.
ON
4 MSEL3
Switch 4 has the following options:
ON (up) = MSEL3 is 0.
OFF (down) = MSEL3 is 1.
ON
5 MSEL4
Switch 5 has the following options:
ON (up) = MSEL4 is 0.
OFF (down) = MSEL4 is 1.
ON
Table 3–1. SW2 DIP Switch Settings (Part 2 of 2)
Switch
Board
Label
Function
Default
Position