Parameter Range Description
Enable rx_10g_frame_skip_err port On/Off When you turn this option On, the 10G
PCS includes the rx_10g_frame_skip_
err output port. This signal is asserted
to indicate the frame synchronization
has received an erroneous word in a
Skip control word location within the
Metaframe. This signal remains asserted
during the loss of block_lock and does
update until block_lock is recovered.
Enable rx_10g_frame_diag_err port On/Off When you turn this option On, the 10G
PCS includes the rx_10g_frame_diag_
err output port. This signal is asserted
to indicate a diagnostic control word
error. This signal remains asserted
during the loss of block_lock and does
update until block_lock is recovered.
Enable rx_10g_frame_diag_status port On/Off When you turn this option On, the 10G
PCS includes the rx_10g_frame_diag_
status 2-bit output port per channel.
This port contains the lane Status
Message from the framing layer
Diagnostic Word, bits[33:32]. This
message is inserted into the next
Diagnostic Word generated by the
frame generation block.
Interlaken CRC32 Generator and Checker
CRC-32 provides a diagnostic tool on a per-lane basis. You can use CRC-32 to trace interface errors back
to an individual lane. The CRC-32 calculation covers the whole metaframe including the Diagnostic
Word itself. This CRC code value is stored in the CRC32 field of the Diagnostic Word. The following
table describes the CRC-32 parameters.
Table 14-28: Interlaken CRC32 Generator and Checker Parameters
Parameter Range Description
Enable Interlaken TX CRC32 Generator On/Off When you turn this option On, the TX
10G PCS datapath includes the CRC32
function.
Enable Interlaken RX CRC32 Generator On/Off When you turn this option On, the RX
10G PCS datapath includes the CRC32
function.
Enable rx_10g_crc32_err port On/Off When you turn this option On, the 10G
PCS includes the rx_10g_crc32_err
port. This signal is asserted to indicate
that the CRC checker has found an error
in the current metaframe.
14-38
10G PCS Parameters for Arria V GZ Native PHY
UG-01080
2015.01.19
Altera Corporation
Arria V GZ Transceiver Native PHY IP Core
Send Feedback
Przeglądanie stron 448
1 2 ... 444 445 446 447 448 449 450 451 452 453 454 ... 701 702

Komentarze do niniejszej Instrukcji

Brak uwag

Unified Brands Vaporiera manuali utente

La lista di Unified Brands Vaporiera prodotti contiene 2 manuali utenti per 2 modelli. Tutte le guide utenti pdf sono disponibili per essere scaricate o visionate online.

Cliccare su un alfabeto di seguito per far scorrere la lista completa dei modellif models starting with that letter

Modelli Tipo di Documento