GUI Parameter Parameter Condition Value Description
Input Register > What
is the source for clock
input?
SIGNED_
REGISTER_B
Input
Representation >
More Options
Clock0–Clock3 Specifies the source for
clock input.
Input Register > What
is the source for
asynchronous clear
input?
SIGNED_
ACLR_B
Input
Representation >
More Options
Aclr0–Aclr2
None
Specifies the source for
asynchronous clear
input.
Pipeline Register >
What is the source for
clock input?
SIGNED_
PIPELINE_
REGISTER_B
Input
Representation >
More Options
Clock0–Clock3 Specifies the source for
clock input.
Pipeline Register >
What is the source for
asynchronous clear
input?
SIGNED_
PIPELINE_
ACLR_B
Input
Representation >
More Options
Aclr0–Aclr2
None
Specifies the source for
asynchronous clear
input.
Table 6-2: ALTMULT_ADD Parameters - Extra Modes
This table lists the IP core parameters applicable to MAX 10 devices.
GUI Parameter Parameter Condition Value Description
Create a shiftout
output from A input of
the last multiplier
On or Off Turn on to create a
signal from A input.
Create a shiftout
output from B input of
the last multiplier
On or Off Turn on to create a
signal from B input.
Register output of the
adder unit
On or Off Turn on to create a
register output of the
adder unit.
What is the source for
clock input?
OUTPUT_
REGISTER
Outputs
Configuration
> Register
output of the
adder unit =
On
Outputs
Configuration
> More
Options
Clock0–Clock3 Specifies the clock
signal for the output
register.
UG-M10DSP