Altera Mentor Verification IP Altera Edition AMBA AXI4-Li Instrukcja Użytkownika Strona 261

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 413
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 260
VHDL Slave BFM
get_write_addr_cycle()
Mentor Verification IP AE AXI4-Lite User Guide, V10.3
261
April 2014
get_write_addr_cycle()
This blocking procedure waits until the write address channel AWVALID signal is asserted.
Example
// Wait for the AWVALID signal to be asserted.
bfm.get_write_addr_cycle(bfm_index, axi4_tr_if_0(bfm_index));
Prototype
procedure get_write_addr_cycle
(
bfm_id : in integer;
path_id : in axi4_adv_path_t; --optional
signal tr_if : inout axi4_vhd_if_struct_t
);
Arguments
bfm_id BFM identifier. Refer to “Overloaded Procedure Common Arguments
on page 151 for more details.
path_id (Optional) Parallel process path identifier:
AXI4_PATH_5
AXI4_PATH_6
AXI4_PATH_7
Refer to “Overloaded Procedure Common Arguments” on page 151 for
more details.
tr_if Transaction signal interface. Refer to “Overloaded Procedure Common
Arguments” on page 151 for more details.
Returns
None