2–8 Chapter 2: Board Components
MAX II CPLD EPM2210 System Controller
Stratix IV E FPGA Development Board Reference Manual May 2011 Altera Corporation
3.3V_PG
2.5-V E8 — U9.G12 3.3-V power good monitor
CLK100_EN
2.5-V J1 — SW1.3, X2.1 100 MHz oscillator enable
CLK125_EN
2.5-V J2 — SW1.4, X4.1 125 MHz oscillator enable
CLK50_EN
2.5-V H3 — SW1.1, X5.1 50 MHz oscillator enable
CLK66_EN
2.5-V H4 — SW1.2, X3.1 66 MHz oscillator enable
CLK66_SEL
2.5-V L14 — SW2.8, U22.3 DIP-clock select SMA or oscillator
CLKIN_50
2.5-V J12 J12 X5.3 50 MHz clock input
CLKIN_MAX_100
2.5-V H12 — Y2.3
100 MHz oscillator to the MAX II
CPLD EPM2210 System Controller
FACTORY_CONFIGn
2.5-V A10 — S2.2
Load factory or user design at
power-up
FLASH_ADVn
2.5-V L13 D20 U2.F6
FSM bus flash memory address
valid
FLASH_CEn
2.5-V K14 K25 U2.B4 FSM bus flash memory chip enable
FLASH_CLK
2.5-V L15 K24 U2.E6 FSM bus flash memory clock
FLASH_OEn
2.5-V M16 K23 U2.F8
FSM bus flash memory output
enable
FLASH_RDYBSYn
2.5-V L11 C20 U2.F7 FSM bus flash memory ready
FLASH_RESETn
2.5-V M15 G21 U2.D4 FSM bus flash memory reset
FLASH_WEn
2.5-V L12 L22 U2.G8 FSM bus flash memory write enable
FPGA_CONF_DONE
2.5-V E3 AH29 — FPGA configuration done
FPGA_CONFIGn
2.5-V E4 AE25 — FPGA configuration active
FPGA_DATA0
2.5-V D3 T28 — FPGA configuration data
FPGA_DATA1
2.5-V L1 T27 — FPGA configuration data
FPGA_DATA2
2.5-V K5 R34 — FPGA configuration data
FPGA_DATA3
2.5-V L2 R33 — FPGA configuration data
FPGA_DATA4
2.5-V K4 T25 — FPGA configuration data
FPGA_DATA5
2.5-V M1 T24 — FPGA configuration data
FPGA_DATA6
2.5-V K3 T32 — FPGA configuration data
FPGA_DATA7
2.5-V M2 R31 — FPGA configuration data
FPGA_DCLK
2.5-V C2 AL3 — FPGA configuration clock
FPGA_STATUSn
2.5-V C3 AH28 — FPGA configuration ready
FSM_A0
2.5-V N9 F22 — FSM bus address
FSM_A1
2.5-V T8 H23 U2.A1 FSM bus address
FSM_A2
2.5-V T9 G23 U3.R6, U2.B1 FSM bus address
FSM_A3
2.5-V R9 F23 U3.P6, U2.C1 FSM bus address
FSM_A4
2.5-V P9 D27 U3.A2, U2.D1 FSM bus address
FSM_A5
2.5-V T10 D28 U3.A10, U2.D2 FSM bus address
FSM_A6
2.5-V P13 F25 U3.B2, U2.A2 FSM bus address
Table 2–5. MAX II CPLD EPM2210 System Controller Device (U10) Pin-Out (Part 2 of 5)
Schematic Signal Name
I/O
Standard
EPM2210
Pin Number
Stratix IV E
Device
Pin Number
Other
Connections
Description
Komentarze do niniejszej Instrukcji