Table 6-8: ALTPLL Output Ports for MAX 10 Devices
Port Name
(11)
Condition Description
activeclock
Optional Specifies which clock is the primary reference clock
when the clock switchover circuit initiates.
If the inclk0 is in use, the activeclock port goes
low. If the inclk1 is in use, the activeclock port
goes high.
You can set the PLL to automatically initiate the
clock switchover when the primary reference clock
is not toggling correctly, or you can manually
initiate the clock switchover using the clkswitch
input port.
c[]
Required The clock output of the PLL.
clkbad[]
Optional clkbad1 and clkbad0 ports check for input clock
toggling.
If the inclk0 port stops toggling, the clkbad0 port
goes high. If the inclk1 port stops toggling, the
clkbad1 port goes high.
(11)
Replace the brackets, [], in the port name with an integer to get the exact name (for example, c0 and c1).
6-8