Przeglądanie stron 82
Port Name Condition Description
pll_scanclkena
Optional This port acts as a clock enable for the scanclk port on
the PLL to be reconfigured.
Reconfiguration begins on the first rising edge of pll_
scanclk after pll_scanclkena assertion. On the first
falling edge of pll_scanclk, after the deassertion of the
pll_scanclkena signal, the IP core stops scanning data
to the PLL.
pll_scandata
Required Drives the scandata port on the PLL to be reconfigured.
This output port from the IP core holds the scan data
input to the PLL for the dynamically reconfigurable bits.
The pll_scandata port sends scandata to the PLL. Any
activity on this port can only be observed when the
reconfig signal is asserted.
ALTPLL_RECONFIG Counter Settings
Table 7-4: counter_type[3..0] Settings for MAX 10 Devices
Counter Selection Binary Decimal
N 0000 0
M 0001 1
CP/LF 0010 2
VCO 0011 3
C0 0100 4
C1 0101 5
C2 0110 6
C3 0111 7
C4 1000 8
Illegal value 1001 9
Illegal value 1010 10
Illegal value 1011 11
Illegal value 1100 12
Illegal value 1101 13
Illegal value 1110 14
Illegal value 1111 15
UG-M10CLKPLL
2015.05.04
ALTPLL_RECONFIG Counter Settings
7-7
ALTPLL_RECONFIG IP Core References
Altera Corporation
Send Feedback