Table 7-3: ALTPLL_RECONFIG Output Ports for MAX 10 Devices
Port Name Condition Description
data_out[]
Optional Data read from the cache when read_param is asserted.
This 9-bit output bus provides the parameter data to the
user. When the read_param signal is asserted, the values
on counter_type[] and counter_param[] determine the
parameter value that is loaded from cache and driven on
the data_out[] bus. When the IP core deasserts the busy
signal, the appropriate bits of the bus (for example,[0] or
[3..0]) hold a valid value.
busy
Optional Indicates that the PLL is reading or writing a parameter to
the cache, or is configuring the PLL.
While the busy signal is asserted, no parameters can be
read or written, and no reconfiguration can be initiated.
Changes to the IP core can be made only when the busy
signal is not asserted. The signal goes high when the
read_param, write_param, or reconfig input port is
asserted, and remains high until the specified operation is
complete. In the case of a reconfiguration operation, the
busy signal remains high until the pll_areset signal is
asserted and then deasserted.
pll_areset
Required Drives the areset port on the PLL to be reconfigured.
The pll_areset port must be connected to the areset
port of the ALTPLL IP core for the reconfiguration to
function correctly. This signal is active high. The pll_
areset is asserted when pll_areset_in is asserted, or,
after reconfiguration, at the next rising clock edge after
the scandone signal goes high. If you use the ALTPLL_
RECONFIG IP core, use the pll_areset output port to
drive the PLL areset port.
pll_configupdate
Optional Drives the configupdate port on the PLL to be reconfig‐
ured. When asserted, the pll_configupdate port loads
selected data to PLL configuration latches. The signal is
asserted after the final data bit is sent out.
pll_scanclk
Required Drives the scanclk port on the PLL to be reconfigured.
For information about the maximum scanclk frequency
for the various devices, refer to the respective device
handbook.
7-6
ALTPLL_RECONFIG Ports and Signals
UG-M10CLKPLL
2015.05.04
Altera Corporation
ALTPLL_RECONFIG IP Core References