
Chapter 4: Functional Description 4–25
Signals
January 2014 Altera Corporation SerialLite II MegaCore Function
User Guide
Table 4–7 on page 4–25 shows the Atlantic interface signals.
f For more information on this interface, refer to the FS13: Atlantic Interface.
1 These signals are only present when the Link Layer mode is enabled and the Atlantic
FIFO buffer is used.
1 There are no specific requirements for Atlantic clocks (
rxrdp_clk
,
rxhpp_clk
,
txrdp_clk
and
txhpp_clk
) as they are all system dependent. The Atlantic clocks at the
read side must be fast enough to prevent backpressure which decreases bandwidth
efficiency.
gxb_powerdown
(5)
Input —
Transceiver block reset and power down. This
signal resets and powers down all circuits in the
transceiver block. This does not affect the refclk
buffers and reference clock lines. All the
gxb_powerdown
input signals of cores placed in
the same transceiver block should be tied
together.The
gxb_powerdown
signal should be tied
low or should remain asserted for at least 2ms
whenever it is asserted.
Notes to Table 4–6:
(1) rxnl is the receive number of lanes; txnl is the transmit number of lanes.
(2) srx is the transfer size × the receive number of lanes.
(3) recon_quad is the total number of Quads being used.
(4) If the
altgx_reconfig
block is not used, the signal will not toggle (set to a fixed value) and thus is not on any clock domain. If the
altgx_reconfig
block is used, this signal is on the
reconfig_clk
domain.
(5) This signal is removed in configurations targeted for Arria V and Stratix V devices due to the exclusion of hard transceivers.
Table 4–6. Transceiver Megafunction Signals (Part 3 of 3)
Signal
(1)
,
(2)
Direction Clock Domain Description
Table 4–7. Atlantic Interface Signals (Part 1 of 3)
Signal Direction Clock Domain Description
rxrdp_clk
(1)
Input — Atlantic receive regular data port clock.
txrdp_clk
Input — Atlantic transmit regular data port clock.
rxhpp_clk
(1)
Input — Atlantic receive high priority port clock.
txhpp_clk
Input — Atlantic transmit high priority port clock.
rxrdp_ena
(1)
Input
rxrdp_clk
Enable signal on the Atlantic interface. Indicates that
the data is to be read on the next clock cycle.
rxrdp_dav
(1)
Input
rxrdp_clk
Input (No FIFO buffer) determines whether flow
control is required on this port. When this signal is
low, the fill level has been breached. When this signal
is high, the FIFO buffer has enough space for more
words.
rxrdp_dav
(1)
Output
rxrdp_clk
Output (With FIFO buffer) represents the buffer’s fill
level. This signal is high when the level is above FTL
or if an EOP is in the buffer.
rxrdp_val
(1)
Output
rxrdp_clk
The output data is valid.
rxrdp_sop
(1)
Output
rxrdp_clk
Start of packet indicator on the Atlantic interface.
Komentarze do niniejszej Instrukcji